Send Inquiry
Blood Bank Refrigerator

Blood Bank Refrigerator

Product Details:

X

Product Description

BBR 150/180

BBR 300/500

BBR 100/150

BBR 100/200


Blood Bank Refrigerator

Features

  • Constructed in double wall-PUF insulated
  • Exterior: G CRCA MS sheet 1.2mm
  • Interior: Stainless steel 22G
  • Full front opening door
  • Doubled walled typed with transparent full view Tufund glass door
  • Magnetic SS lining on gate to prevent heat loss
  • Door: Fitted on the chamber by heavy-duty hinges
  • Gaskets on the door
  • Fitted with castor lockable wheels for ease of mobility
  • Locking arrangement

Technical Specifications

Model

Capacity

Internal Size(WxDxH)

External Size(WxDxH)

Ground Space (WxD)

Weight

BBR 20

20-30 standard Blood bags

362.5x225x625 in mm approx

612.5x380x1175in mm approx

612.5x380in mm approx

Approx 90 kg

BBR 50/60

50-60 standard blood bags

438x375x625in mm approx

625x512.5x1062.5in mm approx

625x512.5in mm approx

Approx 120 kg

BBR 150/180

150 standard blood bags

575x515x1025in mm approx

837.5x638x1500in mm approx

837.5x638in mm approx

Approx 160 kg

BBR 300/350

300 standard blood bags

675x625x1225in mm approx

890x925x1350in mm approx

890x925in mm approx

Approx 240 kg

Construction: This is double walled cabinet PUFF insulated with 75mm thick blanket super glass wool between interior and exterior walls. Outer chamber made of MS and painted with white stoved enamel. The inner chamber made of anodized aluminum with shelf supports allowing wide range of shelf positions and spacing. Supplied with three removable perforated anodized aluminum shelves. Outer double walled flush fitting insulated door with magnetic gasket lock and key fitted with unbreakable transparent acrylic inside door allows inspection of samples with out disturbing temperature of working chamber. Door operated illumination lamp. Cabinet is mounted on castor wheels.

Operation: Temperature is controlled by an imported double action hydraulic type thermostat from 5degC to 50degC in the variation of +/-1 deg C. The evaporator coil, sealed heating element and thermostat-sensing element are provided in the air duct at the back near the top wall in the working space. Inside air circulating system is provided by a F.H Motor with a fan which keeps uniform temperature through out the chamber. A L shape prismatic thermometer duly graduated from 0 deg C to 50 deg C is given on the top to chamber. A quiet running sealed compressor with all its protective devices along with a fan cooled condensing coil are placed below the incubator. Built in safety thermostat prevents damage to samples in case of temperature controller malfunctioning.

Control panel: Control panel is provided at the top of the cabinet with three Nos. indicator for main. Heating, Cooling and protective fuses, volt meter, Temperature setting knob, thermometer, selective switch for above and below ambient temperature in B.O.D incubator economy automatic and self illuminated mains On/Off switch suitable to work on 220/230 volts A.C 50 cycles. Unit will be supplied with appropriate voltage stabilizers.

Temp. Controller: A additional digital temperature controller with its accessories should be fixed to cut off automatically either heating or cooling system when the ambient temperature increases or decreases from the set temperature of the chamber instead of selective switch for above and below. Voltage stabilizer also provided with such equipment.

Extra Features

Digital Temp: Microprocessor based digital temperature controller cum indicator used for controlling 2o to 6oC 1oC, accuracy: 0.1oC, Fan fitted win the inner side for proper air circulation in chamber.

Air circulation: Having provision for Air Circulation through internal fan facility

Inspection lamp: One low watt bulb for internal inspection automatically/manual operated

Cooling unit: Kirloskar/Coplenad ISI make compressor, which is CFC free. Having stand by refrigeration system in case of regular system failing.

Power supply: 230 volts, Single phase 50Hz

Trays/Shelves: No of trays 3 to 6 in S.S for proper storage of blood bags. It is fitted on imported telescopic channels.

Safety: Electronic safety device, Audio visual alarming case of power failure, Opening the door, and in case of high and low internal temperature of BBR, Low and high voltage protector

Optional Accessories: Weekly circular chart recorder for continuous temp. recording weekly temperature circular chart recorder(range -10oC to +10oC), Accuracy: 0.2oC, for temp. Display visually and for continuous temperature monitoring.

Voltage stabilizer.

 

 



116, Sikaa Galaxy, 1st Floor, Shrestha Vihar, Delhi - 110092, India
Phone :View Number
Mr. Ashoke Kumar Sen
Mobile :View Number
Mr. Bhuwan Verma
Mobile :View Number