Hemodialysis Machine Price And Quantity

  • 350000 INR

Product Description

Hemodialysis Machine

  • Assured adequacy with the OCM
  • Dialysate ultrafiltration with Diasafe Plus
  • Compatible with all types of HD disposables
  • Proven reliability
  • Backed by Fresenius medical care service excellence.

Technical Specifications


Dimensions

1370x480x480mm (HxWxH)
(depth of pedestal 630mm )
Weight approx. 86 kg
Water supply
Water inlet pressure
Water inlet temperature
Max. drain height


1.5-6.0 bar
5oC-30oC
1m
Concentrate supply
Supply pressure


1m suction height

Electrical data
Power supply
Current consumption
Power supply
Current consumption


230V +10%, 47-63 Hz
max, 9A
110, V+10%, 47-63Hz
Max. 15A

External connections

Alarm in: Zero potential alarm inlet
Alarm out: Zero potential alarm outlet

Extracorporeal circuit




Arterial pressure monitoring
Display range
Accuracy
Resolution


-300mmHg to +280mmHg
+10mmHg
20 mmHg
Venous pressure monitoring
Display range
Accuracy
Resolution


-60mmHg to +520 mmHg
+10mmHg
20 mmHg
Transmembrane pressure monitoring
Display range
Resolution


-60mmHg to +520mmHg
20mmHg
Arterial blood pump
Blood flow range
Accuracy


15 to 600 mL/min in 8mm bloodline systems
+10%

Air bubble detector

By ultrasound transmission, additional optical monitoring in venous clamp

Heparin pump
Delivery range
Bolus function
Syringe size


0 to 10 mL/h
Max. 5mL per bolus
20mL

Dialysis fluid circuit


Dialysis fluid flow range
Selectable


0-300-500-800 mL/min

Dialysis fluid temperature
Selectable


35oC to 39oC

Dialysis fluid conductivity
Range
Accuracy


12.8 to 15.7 mS/cm (25oC)
+0.1 mS/cm
Acid concentration dialysis fluid
Default mixing ratio
Range


1+34 (others possible)
125 to 150 mmo I/L
Bicarbonate concentration dialysis fluid
Default mixing ratio
Range


1+27.6 (other possible)
-8 to +8 mmol/L bicarbonate

Bicarbonate dry concentrate

bibag@5008

Ultrafiltration
UF rage
Accuracy
Allowed dialyser UF factor unlimited
Parameters displayed


0 to 4.00 I/h
+1%

UF goal, UF time, UF rate, UF volume
Blood leak detector
Sensitivity

<0.5mL blood/min (Hct=25%) at max. flow 800 mL/min

Accuracy clearance K
Disinfection and cleaning programmes

+5%

Integrated hot rinse
Temperature/flow


84oC/450 mL/min